83
Note any privacy accessories used with fences may potentially render the fence more susceptible to the effects of wind
Consult our installation recommendations on p 121
INSTALLATION PROCEDURE
Simple and intuitive installation:
To prevent the slats twisting, we recommend installation as soon as the coil is unwound.
WOOD IS A LIVING MATERIAL
Pockets of resin small knots or splits
are normal characteristics specific to
wood
The colour of the slats may change
becoming slightly grey this is
not a defect it is a natural wood
characteristic
Note cutting the reinforcements may be
necessary for installation on smallfold panels
Position an intermediate slat
in the centre of the panel and
directly screw the slat onto the
reinforcement Then screw on the
slats already positioned on the
reinforcements.
Make sure to adjust the height of
the slats.
r i
4
1
i termé re
e fort.
– épét r l opé
Slide the 2 end slats and an intermediate slat in the
centre of the panel.
1
d ext
To secure the installed slats, attach the bottom reinforcements
to each slat above the fold aligning them with the f irst
horizontal wire. Make sure to add the height of the slats.
2
Bois de p n traité autoclave classe 4
X Ø ,2 , gu
2
n s n é s
a e d la bot
ds p s
u de
u u aue sus du p i s
so e i h izontal
a
m
mett e à n veau
Attach the top reinforcement to each slat below the fold
aligning it with the last horizontal wire For heights ≥
150 m attach the middle reinforcement above the fold
aligning them with the f irst horizontal wire
3
Vis INOX Ø 3,2
autoc ave
é c
mo tage d l é e c ag e a
Pour p nneau g ands p
s
Pou a i a tes
tallées f xer ch que la tes e
r s d audes us d pli
r il
er à a uster la au eur des
tes
c q
d ut en d
so dernier fi ho
t
du milieu au
son premie f l
on ueur 40 mm
P n i à mett e à ive
Attach each of the slats to the reinforcements with
stainless steel screws dia32mm length 40 mm
M3x40 Ensure the slats are properly levelled
4
1- Slide the reinforcement elements
horizontally into the folds.
2 - To maintain the installed
reinforcement elements, slide an
intermediate slat in the centre of the
reinforcement.
3 - Repeat the operation on the 2
nd
half of the panel.
e
i
t s u s
Préconisatio du kit petits p is
1
2
3
1 2 3
Attach each of the intermediate
slats to the reinforcements with
stainless steel screws, dia. 3.2 mm,
length 40 mm (M3x40).
Ensure the slats are properly
levelled.
o ontalem t ans l s
5
KIT FOR LARGE-FOLD PANELS
KIT FOR SMALL-FOLD PANELS
ASSOCIATED ACCESSORY
ACTON 32 X 40 MM
STAINLESS STEEL A2
COUNTERSUNK HEAD
CLADDING SCREWS